Complete calibration and repair of Stahlwille torque wrenches.
Why calibration is required ?
Calibration is the regular examination of the accuracy and
reliability of torque tools.
This is done using special purpose calibrating equipment
which is subject to stringent monitoring.
This is essential because torque tools are precision
instruments which are very often in use in safety relevant
environments. They are expected to provide the same level of
accuracy in their readings reliably over long periods of
time.
In order to ensure these standards are guaranteed, it is
essential that examination by means of calibration takes
place at regular intervals and is documented
Equipment available for calibration
At the very least, a calibration system must include the
following components.

1. Mechanical loader
The mechanical loader is required for rapid, accurate fixing
and operation of the torque wrench. The mechanical loader
also ensures that the DIN EN ISO 6789 requirement for
clicking torque wrenches is fulfilled, i.e. that, above 80%
of the final torque value, the force is applied slowly and
steadily within a period of 0.5 to 4 seconds

2. Transducer
The torque applied using the torque wrench is digitalised
within the transducer and transmitted via USB cable to the
PC, which ensures error-free transmission.

3. USB hub and USB cable
Up to 5 transducers can be connected to the USB hub. From
here, the data are transferred to the PC.

4. Cable
You will require 1 cable fitted with jack plugs for each
transducer which is permanently connected up.

5. Square drive adapter
The set includes the square drive adapters necessary to make
full use of the measuring range of the transducers; e.g. for
transducer No 7723-3 (internal square drive 3/4”), square
drive adapter No 7787 (1/4” female to 3/4” male), No 7788
(3/8” female to 3/4” male) and No 7789 (1/2” female to 3/4”
male).

6. Software
The data received in this way can then be used to issue a
calibration certificate in accordance with DIN/ISO 6789.